← Orthopedic research
RESEARCH PROTOTYPE
Iliac wing.
A localized defect cut into the upper left iliac wing.
Download reference model 3MF · mm
42.18 cm³Reference volume
0.000Proposal Dice overlap
0%Target coverage
1 NReference axial load
What we tested.
- Source and defect
- Source specimen s0370. An ellipsoidal cut removed 42.18 cm³. Its original shape provides the known reference for this experiment.
- Bench model
- The reference download is a closed surface with 515,008 triangles in millimetres. After smoothing, the 95th-percentile sampled surface distance from the original reference was 0.333 mm.
- Reconstruction experiment
- The generated surface missed the entire removed region. The interactive surface shows the known removed anatomy.
- Bench simulation
- The blue reference underwent a two-resolution bench test with nominal homogeneous unfilled PEEK properties. One end band was held fixed and the other carried a 1 N axial pull. The fine solve used 43,846 elements and gave a maximum displacement of 0.0000425 mm. Two conduction solves held one end at 37 °C and the other at 20 or 45 °C, with insulated free surfaces. The field views preserve the surface used by the solver. Downloads contain the smoothed bench geometry.
- Next experiment
- Test anatomy-specific training and compare reconstructions on independent specimens before evaluating candidate mechanics.
Threshold comparison
Each threshold produced a separate model run. We compared the full output and its largest connected component against the known reference.
| Threshold | Surface | Dice overlap |
|---|---|---|
| 0.50 | Full output | 0.000 |
| 0.50 | Largest component | 0.000 |
| 0.25 | Full output | 0.000 |
| 0.25 | Largest component | 0.000 |
| 0.75 | Full output | 0.000 |
| 0.75 | Largest component | 0.000 |
Wasserthal et al. · University Hospital Basel · Annotated CT dataset v2.0.1 · CC BY 4.0 Adaptations include digital defect creation, surface extraction and field mapping. Annotated CT dataset v2.0.1 · CC BY 4.0