← Drug delivery and diagnostics research

RESEARCH PROTOTYPE

Femoral depot.

A synthetic recess in a CT-derived left femur defines a reference envelope for an idealized tracer depot.

Download reference model 3MF · mm
Removed reference volume lifted from the left femur.
3.02 cm³Reference volume
0.000Proposal Dice overlap
0%Target coverage
1 NReference axial load

What we tested.

Source and defect
Source specimen s0370. An ellipsoidal cut removed 3.02 cm³. Its original shape provides the known reference for this experiment.
Bench model
The reference download is a closed surface with 268,544 triangles in millimetres. After smoothing, the 95th-percentile sampled surface distance from the original reference was 0.371 mm.
Reconstruction experiment
The generated surface missed the entire removed region. The interactive surface shows the known removed anatomy.
Bench simulation
The blue reference underwent a two-resolution bench test with nominal homogeneous unfilled PEEK properties. One end band was held fixed and the other carried a 1 N axial pull. The fine solve used 43,814 elements and gave a maximum displacement of 0.000112 mm. Two conduction solves held one end at 37 °C and the other at 20 or 45 °C, with insulated free surfaces. The field views preserve the surface used by the solver. Downloads contain the smoothed bench geometry.
Next experiment
Test anatomy-specific training and compare reconstructions on independent specimens before evaluating candidate mechanics.

Tracer release through a window

We compared three circular openings on the reference depot. A passive tracer diffused at 0.36 mm²/h toward a perfect sink at the window. Every other surface was sealed.

Window radiusReleased at 24 h
2 mm2.59%
4 mm8.21%
6 mm19.59%

The 4 mm window came closest to the illustrative 10% release target. This bench calculation uses an inert tracer with assumed diffusivity.

Threshold comparison

Each threshold produced a separate model run. We compared the full output and its largest connected component against the known reference.

ThresholdSurfaceDice overlap
0.50Full output0.000
0.50Largest component0.000
0.25Full output0.000
0.25Largest component0.000
0.75Full output0.000
0.75Largest component0.000

Wasserthal et al. · University Hospital Basel · Annotated CT dataset v2.0.1 · CC BY 4.0 Adaptations include digital defect creation, surface extraction and field mapping. Annotated CT dataset v2.0.1 · CC BY 4.0