RESEARCH PROTOTYPE
Mandibular body.
An expert-delineated mandible with a local synthetic defect in its body.
Download reference model 3MF · mm
2.23 cm³Reference volume
0.00000635Proposal Dice overlap
0.009%Target coverage
1 NReference axial load
What we tested.
- Source and defect
- Source specimen Pat 1a. An ellipsoidal cut removed 2.23 cm³. Its original shape provides the known reference for this experiment.
- Bench model
- The reference download is a closed surface with 151,936 triangles in millimetres. After smoothing, the 95th-percentile sampled surface distance from the original reference was 0.460 mm.
- Reconstruction experiment
- The generated surface missed almost all of the removed region, covering 0.009% of it. The interactive surface shows the known removed anatomy.
- Bench simulation
- The blue reference underwent a two-resolution bench test with nominal homogeneous unfilled PEEK properties. One end band was held fixed and the other carried a 1 N axial pull. The fine solve used 43,982 elements and gave a maximum displacement of 0.000441 mm. Two conduction solves held one end at 37 °C and the other at 20 or 45 °C, with insulated free surfaces. The field views preserve the surface used by the solver. Downloads contain the smoothed bench geometry.
- Next experiment
- A separate contralateral-registration prototype reached mean Dice 0.717 across six simulated defects in two mandibles, using an operator-defined search box. Independent clinical defects remain to be tested.
Threshold comparison
Each threshold produced a separate model run. We compared the full output and its largest connected component against the known reference.
| Threshold | Surface | Dice overlap |
|---|---|---|
| 0.50 | Full output | 0.00000562 |
| 0.50 | Largest component | 0.000 |
| 0.25 | Full output | 0.00000503 |
| 0.25 | Largest component | 0.000 |
| 0.75 | Full output | 0.00000635 |
| 0.75 | Largest component | 0.000 |
Jürgen Wallner and Jan Egger · Mandibular CT Dataset Collection, v6 · CC BY 4.0 Adaptations include digital defect creation, surface extraction and field mapping. Mandibular CT Dataset Collection, v6 · CC BY 4.0