← Cardiovascular research

RESEARCH PROTOTYPE

Aortic wall.

A synthetic opening through an idealized thoracic aortic wall.

Download reference model 3MF · mmDownload research proposal 3MF · mm
A blue reference patch lifted from the pale aortic wall, showing the missing segment.
1.02 cm³Reference volume
0.749Proposal Dice overlap
71.3%Target coverage
0.1 NReference axial load

What we tested.

Source and defect
Source specimen s0370. A 2.5 mm nominal lining was constructed inside the segmented aortic envelope. An ellipsoidal cut removed 1.02 cm³. Its original shape provides the known reference for this experiment.
Bench model
The reference download is a closed surface with 374,016 triangles in millimetres. After smoothing, the 95th-percentile sampled surface distance from the original reference was 0.278 mm. The smoothed proposal differs from the original prediction by 0.52 mm at the 95th percentile of sampled surface distances. The reconstruction score applies to the original mask.
Reconstruction experiment
The selected proposal recovered 71.3% of the removed region. At threshold 0.25, it reached a Dice overlap of 0.749 against the withheld reference. Candidate selection used the known target from this specimen.
Bench simulation
The blue reference underwent a two-resolution bench test with hypothetical flexible homogeneous polymer properties. One end band was held fixed and the other carried a 0.1 N axial pull. The fine solve used 44,727 elements and gave a maximum displacement of 0.145 mm. Two conduction solves held one end at 37 °C and the other at 20 or 45 °C, with insulated free surfaces. Blood flow and arterial wall mechanics are separate research questions. The selected proposal displaced 0.115 mm under the same fixture assumptions. The field views preserve the surface used by the solver. Downloads contain the smoothed bench geometry.
Next experiment
Test additional vessel shapes and wall assumptions. Vessel flow, pulsatile loading, and anatomical contact each require a separate experiment.
Threshold comparison

Each threshold produced a separate model run. We compared the full output and its largest connected component against the known reference.

ThresholdSurfaceDice overlap
0.50Full output0.730
0.50Largest component0.747
0.25Full output0.728
0.25Largest component0.749
0.75Full output0.732
0.75Largest component0.745

Wasserthal et al. · University Hospital Basel · Annotated CT dataset v2.0.1 · CC BY 4.0 Adaptations include digital defect creation, surface extraction and field mapping. Annotated CT dataset v2.0.1 · CC BY 4.0